Selection table & Outer dimensions
Selection table
Model
No. |
Bore
(mm)
|
Total head
(m)
|
50Hz 1500 (rpm)
|
Total head
(m)
|
60Hz 1800 (rpm)
|
10
|
15
|
20
|
25
|
30
|
40
|
15
|
20
|
30
|
40
|
50
|
60
|
Motor
(kW)
|
Capacity (L/min)
|
Motor
(kW)
|
Capacity (L/min)
|
UT-X120
|
40
|
1.5
|
50
|
30
|
20
|
000
|
000
|
000
|
1.5
|
50
|
35
|
15
|
000
|
000
|
000
|
UT-X220
|
40
|
1.5
|
000
|
50
|
30
|
18
|
000
|
000
|
2.2
|
000
|
100
|
70
|
40
|
000
|
000
|
UT-X320
|
50
|
2.2
|
000
|
110
|
90
|
70
|
40
|
000
|
3.7
|
000
|
140
|
105
|
70
|
30
|
000
|
UT-X520
|
50
|
3.7
|
000
|
000
|
115
|
100
|
85
|
55
|
5.5
|
000
|
000
|
130
|
110
|
85
|
50
|
Outer dimensions
Model
No.
|
Motor
(kW)
|
Dimensions
|
Pump weight
(kg)
|
A
|
B
|
C
|
D
|
E
|
F
|
G
|
J
|
K
|
N
|
L
|
M
|
P
|
P'
|
Z
|
n
|
X
|
UT-X120
|
1.5
|
103
|
143
|
135
|
115
|
105
|
185
|
314
|
152
|
110
|
350
|
570
|
250
|
50
|
14
|
15
|
3
|
90
|
35
|
UT-X220
|
1.5
|
103
|
143
|
135
|
115
|
105
|
185
|
314
|
152
|
110
|
350
|
570
|
250
|
50
|
14
|
15
|
3
|
90
|
35
|
2.2
|
103
|
143
|
135
|
115
|
105
|
190
|
348
|
152
|
120
|
390
|
630
|
280
|
55
|
18
|
15
|
3
|
100
|
35
|
UT-X320
|
2.2
|
125
|
155
|
135
|
140
|
130
|
190
|
348
|
155
|
120
|
390
|
630
|
280
|
55
|
18
|
15
|
3
|
100
|
42
|
3.7
|
125
|
155
|
135
|
140
|
130
|
190
|
376
|
160
|
120
|
390
|
630
|
280
|
55
|
18
|
15
|
3
|
112
|
42
|
UT-X520
|
3.7
|
125
|
155
|
135
|
140
|
130
|
190
|
376
|
160
|
120
|
390
|
630
|
280
|
55
|
18
|
15
|
3
|
112
|
48
|
5.5
|
125
|
155
|
135
|
140
|
130
|
205
|
445
|
140
|
150
|
480
|
780
|
330
|
70
|
25
|
19
|
3
|
132
|
48
|
Note:
Flange dimensions are based on JIS 10K.
Notes for operation
|

|
At initial operation after installation, please remove the priming plug
on the upper part of the pump casing and fill the pump with water.
|

|
If there is the possibility of freezing in the pump casing when the pump
is stopped under freezing conditions, remaining water inside the pump should
be drained off by removing the drain plug on the lower part of the casing.
|

|
It is characteristic of this type of pump that capacity decreases and horse
power increases when total head is high, therefore please make sure that
the valve on the discharge side is not shut off during operation.
|

|
Installation and piping: Please install an inverse U-bent pipe as suction
piping for efficient self-priming. For details, please refer to the page
for the UHN type.
|
Specifications stated here may be subject to change without notice due
to product improvement.
|
|